Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Campbell Scientific Weather Station
Started: 2019-10-215-minute measurements of weather variables taken at Vassar Farm and Ecological Preserve at Collins Field Station. Note that TIMESTAMP represents the DateTime for the previous 5 minutes.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information AirT_Mean AirT_Mean Mean Air Temperature
Ratio Units: deg C
Precision: 0.001BattV_Samp BattV_Samp Battery Voltage
Ratio Units: Volts
Precision: 0.001DewPt_Mean DewPt_Mean Mean Dewpoint Temperature
Ratio Units: deg C
Precision: 0.001HeatInd_Mean HeatInd_Mean Mean Heat Index
Ratio Units: deg C
Precision: 0.001Precip Precip Total Precipitation
Ratio Units: mm
Precision: 0.001Precip_Tot24 Precip_Tot24 Running total of precipitation since midnight of the current day
Ratio Units: mm
Precision: 0.001RECORD RECORD Record Number
Ratio Units: unitless
Precision: 1RH_Avg RH_Avg Mean Relative Humidity
Ratio Units: percent
Precision: 0.001SoilT10_Mean SoilT10_Mean Mean Soil Temperature of Sensor at 10 cm depth
Ratio Units: deg C
Precision: 0.001SoilT20_Mean SoilT20_Mean Mean Soil Temperature of Sensor at 20 cm depth
Ratio Units: deg C
Precision: 0.001SoilT5_Mean SoilT5_Mean Mean Soil Temperature of Sensor at 5 cm depth
Ratio Units: deg C
Precision: 0.001SolRad_Max SolRad_Max Maximum Solar Radiation
Ratio Units: kW/m^2
Precision: 0.001SolRad_Mean SolRad_Mean Mean Solar Radiation
Ratio Units: kW/m^2
Precision: 0.001SolRad_Min SolRad_Min Minim Solar Radiation
Ratio Units: kW/m^2
Precision: 0.001SolRad_Pot SolRad_Pot Estimate of potential solar radiation (Watts m^-2) calculated using VFEP weather station Lat, Long. & elevation.
Ratio Units: W/m^2
Precision: 0.001SolRad_SD SolRad_SD Standard Deviation of Solar Radiation
Ratio Units: kW/m^2
Precision: 0.001SunHrs_Tot SunHrs_Tot Total Number of Hours of Sun
Ratio Units: hours
Precision: 0.001TIMESTAMP TIMESTAMP Datetime for previous 5 minutes
DateTime Date/Time Format: M/D/YYYY hh:mm WD_Samp WD_Samp Wind Direction
Ratio
Unit: degree
Precision: 0.001WindChl_Mean WindChl_Mean Mean Wind Chill
Ratio Units: deg C
Precision: 0.001WS_Mean WS_Mean Mean Wind Spead
Ratio Units: meters/second
Precision: 0.001WS_SD WS_SD Standard Deviation of Wind Speed
Ratio Units: meters/second
Precision: 0.001WV_MeanS WV_MeanS Wind Vector Scalar Mean Wind Speed
Ratio Units: meters/second
Precision: 0.001WV_RMeanD WV_RMeanD Mean Resultant Wind Vector Direction
Ratio Units: Degrees
Precision: 0.001WV_RMeanS WV_RMeanS Wind Vector Resultant Mean Wind Speed
Ratio Units: meters/second
Precision: 0.001WV_SD_Dir WV_SD_Dir Standard Deviation of Wind Direction
Ratio Units: Degrees
Precision: 0.001Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Air Temperature
Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Global short wave radiation accessory
Campbell Scientific, Model 18356. Leveling base for pyranometer.
Global shortwave radiation
Apogee, Model SP230-L12-PT. All-season heated pyranometer. Accuracy ±5% for daily total radiation
Global shortwave radiation accessory
Campbell Scientific, Model CM225. Mounting stand for pyranometer.
Precipitation accessory
Novalynx, Model 260-953. Alter-type rain gauge wind screen, 36" legs
Precipitation gauge
RM Young, Model 52202-L17-LP13. Heated rain and snow gauge, 0.1mm resolution. Accuracy 2% up to 25 mm h-1 (1 in. h-1) 3% up to 50 mm h-1 (2 in. h-1)
Relative humidity
Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Shield for temperature/relative humidity sensor
RM Young, Model 41003-5. 10-plate radiation shield
Soil moisture & electrical conductivity
Campbell Scientific, Model CS655-17-PT-DS. Soil water content reflectometer (also measures conductivity and temperaure). Readings represent an average of conditions along 12 cm length of rods. Volumtric water content: range 5% to 50%, accuracy ±3% VWC (typical in mineral soils that have solution electrical conductivity ≤ 10 dS/m), precision < 0.05%. Temperature: range -10° to +70°C, acc ±0.5°C, prec ±0.02°C. Conductivity: range for Bulk EC 0 to 8 dS/m, acc ±(5% of reading + 0.05 dS/m), prec 0.5% of BEC.
Soil temperature at 10cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Soil temperature at 20cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Soil temperature at 5cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Wind
RM Young, Wind Sentry, Model 03101-5
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
No site characteristics recorded for this dataset