<?xml version="1.0" encoding="UTF-8"?>
<eml:eml xmlns:eml="eml://ecoinformatics.org/eml-2.1.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" scope="system" system="vmc" packageId="vmc.318.309.1" xsi:schemaLocation="eml://ecoinformatics.org/eml-2.1.1 eml.xsd">
<access authSystem="knb" order="allowFirst" scope="document"> <allow> <principal>public</principal>
 <permission>read</permission>
 </allow>
 </access>
   <dataset><title>Gaseous Elemental, Gaseous Oxidized and Particulate-Bound Mercury Flux</title><creator><organizationName>Forest Ecosystem Monitoring Cooperative</organizationName><address><deliveryPoint>705 Spear Street</deliveryPoint><city>South Burlington</city><administrativeArea>Vermont</administrativeArea><postalCode>05403</postalCode><country>United States of America</country></address><phone>(802) 656-0683</phone><electronicMailAddress>femc@uvm.edu</electronicMailAddress><onlineUrl>www.uvm.edu/femc</onlineUrl></creator><associatedParty><organizationName>National Atmospheric Deposition Program AMNet</organizationName><role>lead</role></associatedParty><associatedParty><organizationName>Vermont Monitoring Cooperative </organizationName><role>partner</role></associatedParty><abstract><para>Flux of gaseous elemental, gaseous oxidized and particulate-bound mercury measured with automated instrumentation at Proctor Maple Research Center</para></abstract><keywordSet><keyword/></keywordSet><contact><organizationName>Forest Ecosystem Monitoring Cooperative</organizationName></contact><project><title>AMNet (Atmospheric Mercury Network): Continuous monitoring of elemental and reactive airborne mercury</title><personnel><individualName><givenName>Carl</givenName><surName>Waite</surName></individualName><role>principalInvestigator</role></personnel><personnel><individualName><givenName>Miriam</givenName><surName>Pendleton</surName></individualName><role>contentProvider</role></personnel><personnel><individualName><givenName>James</givenName><surName>Duncan</surName></individualName><role>principalInvestigator</role></personnel><personnel><individualName><givenName>Mark</givenName><surName>Olson</surName></individualName><role>contentProvider</role></personnel><abstract><para/><para>This project measures atmospheric mercury fractions which contribute to dry and total mercury deposition. Proctor Maple Research Center and VMC participate in a network of sites collecting concentrations of atmospheric mercury species from automated, continuous measuring systems coordinated by the National Atmospheric Deposition Program.</para></abstract><studyAreaDescription/></project><dataTable><entityName>Gaseous Elemental, Gaseous Oxidized and Particulate-Bound Mercury Flux</entityName><entityDescription>Flux of gaseous elemental, gaseous oxidized and particulate-bound mercury measured with automated instrumentation at Proctor Maple Research Center</entityDescription><physical><objectName>VMC.318.309</objectName><dataFormat><externallyDefinedFormat><formatName>mySQL</formatName></externallyDefinedFormat></dataFormat><distribution><online><url>https://www.uvm.edu/femc/CI4/data/archive/project/atmospheric-mercury-network-amnet-continuous-monitoring/dataset/gaseous-elemental-gaseous-oxidized-particulate-bound</url></online></distribution></physical><coverage scope="document"><temporalCoverage scope="document"><rangeOfDates><beginDate><calendarDate>2013-06-12</calendarDate></beginDate><endDate><calendarDate>2016-01-04</calendarDate></endDate></rangeOfDates></temporalCoverage></coverage><attributeList><attribute><attributeName>lampV_Avg</attributeName><attributeLabel>Average lamp voltage</attributeLabel><attributeDefinition>Average voltage of the lamp in the analyzer during sampling</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>RECORD</attributeName><attributeLabel>Record number</attributeLabel><attributeDefinition>Instrument-assigned identification number for the record</attributeDefinition><storageType>int</storageType><measurementScale><interval><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType></numericDomain></interval></measurementScale></attribute><attribute><attributeName>T1baseln</attributeName><attributeLabel>Baseline voltage</attributeLabel><attributeDefinition>Baseline reading emitted by zero air (no mercury)</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>T1blnstd</attributeName><attributeLabel>Baseline voltage standard deviation</attributeLabel><attributeDefinition>Standard deviation of the baseline level</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>T1event</attributeName><attributeLabel>Sample event </attributeLabel><attributeDefinition>Code indicating the type of sample (elemental, reactive, particulate) assayed</attributeDefinition><storageType>int</storageType><measurementScale><nominal><nonNumericDomain><enumeratedDomain><codeDefinition><code>0</code><definition>GEM</definition></codeDefinition><codeDefinition><code>1</code><definition>Flush</definition></codeDefinition><codeDefinition><code>2</code><definition>Pyrolyzer heating</definition></codeDefinition><codeDefinition><code>3</code><definition>PBM2.5 heating </definition></codeDefinition><codeDefinition><code>4</code><definition>GOM heating</definition></codeDefinition></enumeratedDomain></nonNumericDomain></nominal></measurementScale></attribute><attribute><attributeName>T1HgConc</attributeName><attributeLabel>Sample concentration</attributeLabel><attributeDefinition>Concentration of mercury in the sample</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TIMESTAMP</attributeName><attributeLabel>Record timestamp</attributeLabel><attributeDefinition>Time the record was captured</attributeDefinition><storageType>datetime</storageType><measurementScale><dateTime><formatString>YYYY-MM-DD hh:mm:ss</formatString></dateTime></measurementScale></attribute><attribute><attributeName>time_of_year</attributeName><attributeLabel>Day and time of year</attributeLabel><attributeDefinition>Day of year plus decimal representation of hours, minutes and seconds</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType><BoundsGroup><bounds><minimum>0</minimum><maximum>365</maximum></bounds></BoundsGroup></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkCartridge</attributeName><attributeLabel>Instrument cartridge sampled</attributeLabel><attributeDefinition>The cartridge within the instrument from which sample was analyzed</attributeDefinition><storageType>text</storageType><measurementScale><nominal><nonNumericDomain/></nominal></measurementScale></attribute><attribute><attributeName>TkDate</attributeName><attributeLabel>Instrument date</attributeLabel><attributeDefinition>Date as set on the instrument</attributeDefinition><storageType>text</storageType><measurementScale><nominal><nonNumericDomain/></nominal></measurementScale></attribute><attribute><attributeName>Tkhour</attributeName><attributeLabel>Instrument hour</attributeLabel><attributeDefinition>Hour as set on the instrument</attributeDefinition><storageType>int</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType><BoundsGroup><bounds><minimum>0</minimum><maximum>23</maximum></bounds></BoundsGroup></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>Tkmin</attributeName><attributeLabel>Instrument minute</attributeLabel><attributeDefinition>Minutes as set on the instrument</attributeDefinition><storageType>int</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType><BoundsGroup><bounds><minimum>0</minimum><maximum>59</maximum></bounds></BoundsGroup></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkPeakArea</attributeName><attributeLabel>Peak area</attributeLabel><attributeDefinition>Area under the curve recorded by Cold Vapor Atomic Fluorescence Spectroscopy  analysis</attributeDefinition><storageType>int</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkPeakMax</attributeName><attributeLabel>Peak voltage</attributeLabel><attributeDefinition>Maximum voltage obtained during the sample analysis phase</attributeDefinition><storageType>decimal</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkSmpDuration</attributeName><attributeLabel>Sample period duration</attributeLabel><attributeDefinition>Duration of the sampling period</attributeDefinition><storageType>int</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkSmpVolume</attributeName><attributeLabel>Sample volume</attributeLabel><attributeDefinition>Volume of the sample analyzed</attributeDefinition><storageType>int</storageType><measurementScale><ratio><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>integer</numberType></numericDomain></ratio></measurementScale></attribute><attribute><attributeName>TkStatus</attributeName><attributeLabel>Instrument status code</attributeLabel><attributeDefinition>Code indicating nature of operation of each cartridge</attributeDefinition><storageType>text</storageType><measurementScale><nominal><nonNumericDomain/></nominal></measurementScale></attribute><attribute><attributeName>TkTime</attributeName><attributeLabel>Instrument time</attributeLabel><attributeDefinition>Time as set on the instrument</attributeDefinition><storageType>datetime</storageType><measurementScale><dateTime><formatString>other</formatString></dateTime></measurementScale></attribute><attribute><attributeName>TkType</attributeName><attributeLabel>Mode of operation</attributeLabel><attributeDefinition>Type of operation the instrument ran during time period</attributeDefinition><storageType>text</storageType><measurementScale><nominal><nonNumericDomain/></nominal></measurementScale></attribute><attribute><attributeName>T_2537A_C_Avg</attributeName><attributeLabel>Average temperature of analyzer</attributeLabel><attributeDefinition>Analyzer's average temperature during sampling</attributeDefinition><storageType>decimal</storageType><measurementScale><interval><unit><standardUnit>meter</standardUnit></unit><numericDomain><numberType>real</numberType></numericDomain></interval></measurementScale></attribute></attributeList></dataTable></dataset></eml:eml>
